$10

Excellent carpentry skills and electrical tradesman
currently working but under-employed

high end re-model and Mechanical projects

call

or

see resume below

May 24, 2011

Call

&

Trades: Formal cross-training and experience with MEP's -- frame & finish carpentry
40 years total experience / 20 as an electrician & 20 / in general construction
Strengths: Electrical & Frame carpentry -- strong math and organizational skills
Weakness: Dealing with wimps and stupid people!
Call

&

Education & Training
Call

GED while in Army

United States Army 3 years: Clinical laboratory technician
2+ years of college Lindenwood University (Biology Philosophy)
1 year of college St. Mary's University of Texas at San Antonio
ELECTRONICS I & II Linn Technical College Linn, MO.

ARCHITECTURAL DRAFTING Linn Technical College Linn, MO.

MECHANICAL DRAFTING Linn Technical College Linn, MO.

INDUSTRIAL ENGINEERING TECHNICIAN ACF Industries St. Louis,

1993 N.E.C. (by Francis Love) St. Louis Area IEC

1994 ELECTRICAL DESIGN

1996 N.E.C. Code Review
1999 N.E.C. Code Review

2001 CERTIFIED CRANE OPERATOR 23Ton Truck Mounted

Call

References

Interest & Hobbies
Sailing, surfing, chess, building custom computers

Specific Job Experience
Please see following sections for Multi-Trade Experience

Most Recently as a Supervising Journeyman Electrician with Gulf Electric Service Co.
8-8-08 thru 3-8-11 Started @ $10.00/hr. Ending rate $14.25/hr.

Worked on several projects locally including; the remodel and addition to the PJC main campus library,

and two projects on Eglin Air Force Base, and two other school additions.
I was then sent to Petersburg, Va., where I was assigned the duties of electrical foreman; on the Five

Forks Battlefield Monument & Visitor's Center -- a job for the National Parks Service. Again this job

included the complete span of electrical work elements -- but had the distinction of providing experience
with many 'state of the art' systems for Lighting Control, Fire Alarm, Intrusion Alarm, Data/Com and
Fire Pump Control. Additionally I received training for installation & programming by the Simplex rep.
My last assignment was the new ECUA administrative building -- a 50,000sq ft building which included

ndustrial shops, laboratories, a safe area for emergency operations, as well as executive offices and class

rooms. I participated in some of the underground work, and was made responsible for all the above ground

work which included a 1200A 3P 480V draw out transfer switch (for redundant power supply) 20 other

pieces of switchgear and cabinets, 7 transformers, and a 30KW UPS and developed forms and worksheets;

which provided & recorded information for raceway mapping -- pull charts.
Currently assigned as lead electrician on building D of the 125,000sq ft downtown school
ECUA oversight by Dan Carapelluci ()

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>><<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<
As a Multi-Disciplined Tradesman for the Architect, Greg Ustevenes
6-6-06 thru 9-15-07 Started @ $7.50/hr. Ending rate $15.00/hr.

On the Snug Harbor Condominiums, I was assigned to special projects for a 12 story 90 unit condo,

where I responded directly to the architect, effecting changes & corrections. Initially I performed interior

and exterior steel stud framing as part of a 5 man team. I participated in lay-out both on the unit and

structural level. Later worked solo, setting up & operating an on-site pre-fab shop for both wood and

steel applications, where I milled and installed, all 600 sets of door and window bucks, as well as the 200'

of balcony chases on each of the 12 floors, also pre-fabbed, roof components, built all the soffets, and

gables, did some PVC drain work and minor HVAC duct work. I also helped coordinate and facilitate

activities with the electrical contractor. Hung drywall and exterior sheeting products. Often I was

called upon to work extended or unusual hours to facilitate the work of others.
Call

As a Multi-Disciplined Tradesman & Superintendent, for Johnson Contracting (St Louis)
4-4-99 thru 10-10-01 Started @ $8.50/hr. Ending rate $16.00/hr

Audrey Estates, Bulldozed down, two city blocks in downtown St. Louis and built 16 -- 2 story -- 2000 sq.ft. homes. Assisted with, coordinated, and facilitated all sub-contractors thru all phases of the project; from infrastructure planning to completion. Ordered and procured all material for framing and finish. Prepared the vouchers and came to be responsible for cash-flow management. Personally laid-out, and lead all frame and finish carpentry & trained several un-skilled, disadvantaged youth as carpenters. On 5 of the houses I installed all of the duct work -- and on 4 of them I did the shingle roofing. I was trained as a mobile crane operator and operated the crane for the setting of the trusses on 12 of the homes.

Call

Jobs listed below were performed as foreman, superintendent, or owner:

GC/general contractor -- EC/electrical contractor

GC/ AUDREY ESTATES (& Page) 16 -- 2 Story -- 2,000 sq ft homes (also ductwork in 5 of them)

GC/ DESIGNED & BUILT 3rd floor on home in Webster Groves

GC/ EMERALD POINT OFFICE BUILDING, Chesterfield MO 2,500 sq ft tenant finish

GC, EC, HVAC/ CUDDLES DAY CARE CENTER St.L 4,000 sq ft conversion of a SHONEY'S to a 'high-end' day care.

GC + ALL MEP/ WENDY'S Restaurants, Central IL. Remodeled 8 all road trip 3 nights each 7 men)

GC + EC/ AMERITECH Stores w/ Real World Display Package -- also set repeater station and 150 cat 5 outlets

EC + HVAC/ WILBER & GILL'S Restaurant Chesterfield, MO 11,000sq ft high-end restaurant

EC/ FASHION BUG Store Fenton, MO 14,000 sq ft did the wreck out, installed 420 fixtures, 1200 Amp service, 15 tons X3

RTU's Data/com, smokes & fire -- 2 persons 7 weeks helped build and install the sound baffles as well.

EC/ ROYAL OAK RANCH Ballwin, MO 27,000 sq ft, arena, stables & vet. Facility completed in 62 days!

EC/ ST. LOUIS CITY HALL PARKING LOT Wired gate houses and pulled underground feeders 2 X 750 ft 4-30 + 6 run spliceless thru man holes in winter -- using only one other electrician and 3 day laborers

EC/ ST. LOUIS CITY HALL DUPLEX ELEVATOR UPGRADE set transformers, motor/converters, disconnects, control panel -- in attic penthouse -- had to bring all tools and equipment more than 100' thru the attic trusses.

EC/ ST. LOUIS METROPOLITAN POLICE CANINE CENTER w/ transformer private metered facility -- explosion proof

EC/ HOLIDAY INN, Springfield Ill, Upgrade required doubling available wattage to separate wing, was fed underground beneath parking lot -- 110/208 -- re-routed to 277/480 source, then set transformer back to 110/208 & second panel in wing avoided adding 2nd run and tearing up parking lot -- done without shutting down the wing at any time.

EC/ NATIONAL HEALTH CARE CENTER, St. Louis, Mo. set 200 A 277/480 V Sub Feed Drilled and tapped busbars to install breaker -- performed on LIVE EQUIPMENT

EC/ EUREKA EURATHANE set and repaired numerous motors and lathes -- trenched Piped, & pulled 225 A 277/480 V Feeder 150' to new building -- drilled & tapped busbars and install breaker -- source panel at 2000 Amps -- performed on LIVE EQUIPMENT

EC/ NIGHTMARES HAUNTED HOUSE wired 2 years in a row -- 20,000 sq ft of temp Structures, 5 acres of parking lot lights -- 2 mobile homes -- created special effects electronics packages & Stereo, security AND 186 Emergency exit lights

EC/ BI-STATE TRANSIT; installed fuel & additives controlling, dispensing, & monitoring equipment -- utilizing explosion proof wiring methods -- late penalty would have been accessed at $2,500/hr! We finished on time.

Ran my own business, specializing in light commercial re-model
12-12-01 thru 2-10-06 rates varied of course (St. Louis Mo.)

Performed many remodels of areas up to 4,500sq ft starting with demolition, sometimes assisting with the design, often performing all MEP's. Generally I would do all the framing (a lot of steel stud work) hang and tape -- and

on some occasions performed the painting and floor tile work as well. Also built 2 - 2700 sq ft homes

WINDING TRAILS SUB DIV wired 60 customs (2750 sq ft range) solo (2 years) as part of my apprenticeship

Call

&

the primary purpose of this posting is to obtain traditional employment in my areas of experience
I AM NOT A LICENSED CONTRACTOR


The ad is older than 60 days.
Category:  Misc
 |  Address:  Navarre, Florida

Copyright © 2017 Americanlisted.com, All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.